Products
Development packages, conformance test tools, engineering tools and a gateway. Everything is delivered with documentation, sample projects and a source or binary licence — tell us which one your project needs.
IED side
Turn a conventional protection or bay controller into a compliant IEC 61850 IED in one to two weeks.
- Full MMS service set in both roles
- Built-in 61850 modelling for protection and measurement
- Dual-network / dual-host redundancy, GOOSE publish and subscribe
Client side
Bring up to 200 IEDs into your master station or gateway with a few lines per device.
- Designed for 200+ IEDs per station, 10,000+ attributes each
- Model import or automatic discovery to build the device directory
- Millisecond-level data change response when system resources allow
Telecontrol
One code base for serial telecontrol, protection information and TCP/IP SCADA links — plus the tester that ships with it.
- Three standards, one code base, three roles
- Point-table generator: Excel/CSV to information-object addresses and C code
- Fault injection and clause-level conformance reports
Diagnostics
When a channel "occasionally drops a point", this is the tool that tells you which side did it.
- Decode tree from frame to information object, with point-table linkage
- Anomaly detection: sequence jumps, stNum/sqNum problems, length mismatches, negative acknowledgements
- One-click HTML/Word/PDF report suitable as an acceptance annex
Test suite
Every MMS server test case in IEC 61850 clause 10, run exhaustively against your device.
- All IEC 61850 clause 10 MMS server test cases
- Error scenarios: bad parameters, invalid objects, type errors, range errors, abnormal termination
- Limit scenarios: maximum read/write responses per second, maximum report throughput, log storage capacity
Test suite
Simulate one IED or two hundred, then see whether your master station keeps up.
- All clause 10 MMS client test cases
- Automatic data verification and timeliness checks on the substation side
- Data-storm and network-interruption scenarios
Engineering tool
Draw the primary single-line diagram; get a valid IEC 61850 SSD model out of the same file.
- Graphic modelling: the SSD is generated while the diagram is drawn
- Import a standard SSD and regenerate an editable diagram
- Logic node library linked to primary equipment, with virtual terminal tables
Hardware
One box that speaks 101, 102, 103, 104, Modbus, CDT and IEC 61850 — in either direction.
- 101, 102, 103, 104, Modbus, CDT and 61850 MMS/GOOSE in one device
- Master, outstation and remote-control-transparent modes
- Linux platform, Ethernet + CAN + RS-485 + RS-232 interfaces